Elitech Tlog 10H/Tlog 10EH

Elitech Tlog 10H/10EH Digital Temperature and Humidity Data Logger

အသုံးပြုသူလက်စွဲ

1. နိဒါန်း

The Elitech Tlog 10H and Tlog 10EH are digital temperature and humidity data loggers designed for reliable monitoring in various scenarios. These devices offer automatic PDF report generation, USB plug-and-play functionality, and a large memory capacity for up to 32,000 data points. The Tlog 10H features an internal temperature and humidity probe, while the Tlog 10EH includes an external probe for extended measurement flexibility. This manual provides essential information for the proper setup, operation, and maintenance of your data logger.

Elitech Tlog-10H Temperature & Humidity Data Logger

Figure 1: Elitech Tlog-10H Temperature & Humidity Data Logger (Internal Probe Model)

Elitech Tlog-10EH Temperature & Humidity Data Logger

Figure 2: Elitech Tlog-10EH Temperature & Humidity Data Logger (External Probe Model)

  • Automatic PDF Report: Generates PDF reports automatically with embedded data, eliminating the need for special software to view အခြေခံအချက်အလက်။
  • USB plug-and-Play- Direct connection to a computer via USB for data download and report generation.
  • ဒေတာပြသမှု Current temperature, maximum/minimum values, current date, and logging points are visible on the LCD screen.
  • ပြင်ဆင်သတ်မှတ်နိုင်သော ကန့်သတ်ချက်များ- Temperature unit (°C/°F), alarm range, and logging interval are user-configurable.
  • မမ်မိုရီသိုလှောင်မှု- Stores up to 32,000 data points.
  • ရေစိုခံ အဆင့်သတ်မှတ်ချက်- IP65 protection class, offering resistance against dust and water splashes.
  • ခလုတ်ဒီဇိုင်း- Features an anti-touch button design to prevent accidental operations.
  • Software ကိုပံ့ပိုး: Compatible with ElitechLog software for macOS and Windows, and online web page configuration for advanced functions.
  • Logging Modes: Supports 'Stop when full' and 'Circular recording' modes.
  • နှိုးစက်စနစ်- LED indicator and LCD display for alarm notifications.
Tlog 10H features: USB plug-and-play and direct PDF export

Figure 3: USB Plug-and-Play and Direct PDF Export

Tlog 10H features: Anti-touch button design, IP65 waterproof, and 32000 points memory storage

Figure 4: Anti-touch Button Design, IP65 Waterproof, and Memory Storage

Elitechlog software capabilities including data query, chart comparison, settable alarm range, email backup, FDA compliance, and data export

Figure 5: Elitechlog Software Capabilities

3. စနစ်ထည့်သွင်းပါ။

3.1 ကနဦးစစ်ဆေးခြင်း။

Upon receiving your data logger, inspect it for any visible damage. Ensure all components are present, including the data logger unit and, for the Tlog 10EH model, the external temperature and humidity probe.

3.2 ပါဝါဖွင့်ပါ။

The device is powered by a CR2450 button cell battery. Ensure the battery is correctly installed. The LCD screen should activate, displaying current readings.

3.3 Software Installation (Optional, for advanced features)

While basic PDF reports do not require software, for advanced configuration, data query, chart comparison, and data export in formats like Excel or TXT, download the ElitechLog software from the official Elitech website. The software is available for macOS and Windows operating systems. Alternatively, online web page configuration may be available.

3.4 Connecting the External Probe (Tlog 10EH only)

For the Tlog 10EH model, carefully connect the external temperature and humidity probe to the designated port on the data logger. Ensure a secure connection.

Elitech Tlog 10EH with external temperature and humidity probe

Figure 6: Tlog 10EH with External Probe

4. လုပ်ငန်းဆောင်ရွက်မှုညွှန်ကြားချက်များ

4.1 Starting a Recording Session

Press the 'START' button to begin data logging. The device will start recording temperature and humidity data at the configured interval. The LCD will indicate that recording is active.

4.2 Stopping a Recording Session

Press the 'STOP' button to end the current data logging session. The device will cease recording, and the data will be stored in its internal memory.

4.3 Viewing Data on LCD

The LCD screen displays real-time data. You can view the current temperature, humidity, maximum/minimum recorded values, current date, and the number of logging points. The temperature unit can be switched between Fahrenheit and Celsius directly on the device.

4.4 ကန့်သတ်ချက်များပြင်ဆင်ခြင်း။

To change settings such as the logging interval, alarm range, or temperature unit, connect the data logger to a computer via USB and use the ElitechLog software or the online web configuration tool. Follow the on-screen instructions within the software to adjust parameters.

4.5 Downloading Data and Generating Reports

  1. Connect the data logger to your computer's USB port.
  2. The device will automatically generate a PDF report. This report can be accessed directly from the device as a removable drive.
  3. For more detailed analysis or different report formats (Excel, TXT), open the ElitechLog software. The software will detect the connected device and allow you to download the raw data and generate customized reports.
Example of an automatic PDF report generated by the Tlog 10H

Figure 7: Automatic PDF Report Example (Tlog 10H)

Example of an automatic PDF report generated by the Tlog 10EH

Figure 8: Automatic PDF Report Example (Tlog 10EH)

5. ပြုပြင်ထိန်းသိမ်းမှု

5.1 သန့်ရှင်းရေး

ပျော့ပျောင်းသောကိရိယာဖြင့်သုတ်ပါ၊ ဃamp cloth. Do not use abrasive cleaners or solvents. Ensure the USB port and probe connections are free from dust and debris.

5.2 ဘက်ထရီ အစားထိုးခြင်း။

When the battery indicator on the LCD shows low power, replace the CR2450 button cell battery. Carefully open the battery compartment, remove the old battery, and insert a new one with the correct polarity. Dispose of old batteries responsibly.

5.3 သိုလှောင်မှု

Store the data logger in a cool, dry place away from direct sunlight and extreme temperatures when not in use for extended periods.

  • စက်ပစ္စည်းကို ဖွင့်မထားပါ- Check battery installation and charge level. Replace battery if necessary.
  • ဒေတာမှတ်တမ်းတင်ခြင်း မရှိပါ- Ensure the 'START' button was pressed and the device is not in a 'STOP' state. Check if memory is full (if 'Stop when full' mode is selected).
  • Cannot connect to computer/generate report: Ensure the USB connection is secure. Try a different USB port or cable. Restart your computer. Ensure ElitechLog software is up-to-date.
  • မမှန်ကန်သောဖတ်ရှုမှုများ- Ensure the probe (especially external for Tlog 10EH) is properly connected and not obstructed. Allow the device to stabilize in the environment for a few minutes before starting a new log.
  • Alarm not triggering: Verify alarm settings in the ElitechLog software. Check if the LED indicator is functional.

7. သတ်မှတ်ချက်များ

ထူးခြားချက်သတ်မှတ်ချက်
အာရုံခံ အမျိုးအစားInternal/External Temp-Humi 2 in 1
အပူချိန်အတိုင်းအတာ-30 ℃မှ 70 ℃ (-22 ℉မှ 158)
စိုထိုင်းဆ Range0 မှ 100% RH
ဆုံးဖြတ်ချက်0.1 °C/°F; 0.1% RH
ဒေတာအင်တာဖေ့စ်USB
Memory စွမ်းဆောင်ရည်အမှတ် ၃၂,၀၀၀ (အမြင့်ဆုံး)
သစ်ခုတ်ချိန်10 seconds to 24 hours (configurable)
လျှပ်စစ်ဓာတ်အားထုတ်ပေးသောကိရိယာCR2450 ခလုတ်ဆဲလ်ဘက်ထရီ
ဆော့ဝဲElitechLog (macOS/Windows), Online Web စာမျက်နှာဖွဲ့စည်းမှု
ဖော်မတ် အစီရင်ခံပါ။Automatic PDF Report, PDF/EXCEL/TXT via ElitechLog
မှတ်တမ်းမုဒ်Stop when full, Circular recording
နှိုးစက် ဆက်တင်များLED Indicator, LCD Display
အကာအကွယ်အတန်းIP65
အောင်လက်မှတ်EN12830, အီး, RoHS
အတိုင်းအတာ (အနီးစပ်ဆုံး)Width: 1.7in, Height: 3.8in, Thickness: 0.5in
အပူချိန်တိကျမှု±0.9°F (-4F~104°F); ±0.5°C (-20C~40°C); ±1.8°F (-58°F~185°F); ±1.0°C (-50C~85°C)
စိုထိုင်းဆ တိကျမှု±3%RH (25°C: 20%~80%RH); ±5%RH (others)
Tlog 10EH dimensions and accuracy specifications

Figure 9: Tlog 10EH Dimensions and Accuracy

Comparison table of Elitech Tlog models including Tlog10, Tlog10E, Tlog10H, and Tlog10EH, detailing sensor type, logging capabilities, temperature and humidity ranges, record capacity, data export, logging interval, response time, and protection class.

Figure 10: Elitech Tlog Series Model Comparison

၁.၆။ အသုံးပြုသူ အကြံပြုချက်များ

  • အကောင်းဆုံးနေရာချထားမှု- For accurate readings, place the data logger in a location representative of the environment you wish to monitor. Avoid direct sunlight, heat sources, or areas with poor air circulation.
  • External Probe Use: When using the Tlog 10EH, ensure the external probe is positioned correctly within the target environment, especially if monitoring conditions different from the logger's immediate vicinity.
  • ပုံမှန် Data Backup- Periodically download your data to prevent loss and ensure continuous monitoring. The 32,000-point memory is substantial, but regular backups are good practice.
  • ဆော့ (ဖ်) ဝဲပြုပြင်မှု - Utilize the ElitechLog software for precise control over logging intervals and alarm thresholds to tailor the device to your specific monitoring needs.
  • ဘက်ထရီသက်တမ်း- Monitor the battery indicator on the LCD. A fresh CR2450 battery ensures uninterrupted logging, especially for long-duration tasks.

9. အာမခံနှင့် ပံ့ပိုးမှု

For warranty information, technical support, or service inquiries, please contact Elitech customer service or refer to the official Elitech website. သင့်ဝယ်ယူမှုပြေစာအား ဝယ်ယူမှုအထောက်အထားအဖြစ် သိမ်းဆည်းပါ။

ဆက်စပ်စာရွက်စာတမ်းများ - Tlog 10H/Tlog 10EH

အကြိုview Elitech Tlog Series User Manual: Temperature & Humidity Data Loggers
Comprehensive user manual for Elitech Tlog Series reusable PDF data loggers, covering specifications, operation, mobile app usage, and device features for cold chain monitoring.
အကြိုview Elitech Tlog 10 Series User Manual - Data Logger Operation and Specifications
Comprehensive user manual for Elitech Tlog 10 Series data loggers. Details product overview, model selection, technical specifications, and step-by-step operation guide including software setup, parameter configuration, logging, event marking, data download, and logger reuse. Features temperature and humidity monitoring for cold chain logistics.
အကြိုview Elitech Tlog Series User Manual: Temperature and Humidity Data Loggers
User manual for Elitech Tlog series reusable data loggers, covering specifications, operation, and configuration for temperature and humidity monitoring in cold chain logistics, pharmaceuticals, and food transport. Includes details on USB and Bluetooth models.
အကြိုview Elitech RC-51H User Manual: Temperature & Humidity Data Logger
Comprehensive user manual for the Elitech RC-51H multi-use temperature and humidity data logger. Covers product overview, structure, parameters, operating instructions, technical specifications, report generation, and battery replacement.
အကြိုview Elitech IoT & Cold Chain Data Loggers | ပြည့်စုံသော ထုတ်ကုန်ကတ်တလောက်
အပူချိန်၊ စိုထိုင်းဆ နှင့် အစုံသုံးနိုင်သော စက်များ အပါအဝင် Elitech ၏ ကျယ်ပြန့်သော IoT နှင့် အအေးကွင်းဆက်ဒေတာ မှတ်တမ်းများကို စူးစမ်းပါ။ ယုံကြည်စိတ်ချရသော စောင့်ကြည့်မှုနှင့် လိုက်နာမှုအတွက် ဝန်ဆောင်မှုများ၊ နည်းပညာဆိုင်ရာ သတ်မှတ်ချက်များနှင့် ဆော့ဖ်ဝဲဖြေရှင်းချက်များကို ရှာဖွေပါ။
အကြိုview Elitech RC-51H User Manual: Temperature and Humidity Data Logger
Comprehensive user manual for the Elitech RC-51H, a multi-use temperature and humidity data logger. Learn about its features, specifications, operating instructions, and data reporting.