Accsense Ethernet Pro Data Logger
Ethernet Pro Quick Start Guide
- Use this handy guide to help you get started with your new Accsense Ethernet Pro. Have questions? Contact us using the information at the bottom
အာရုံခံကိရိယာများ ချိတ်ဆက်ခြင်း။
The Accsense Ethernet Pro also accepts sensors with voltage or 4-20 mA outputs. Please see the full user guide for information on connecting and configuring these types of sensors.
ပါဝါချိတ်ဆက်ခြင်း။
- The Ethernet Pro is powered by either Power over Ethernet (POE) or the USB connection using the AC adapter and USB cable supplied with the unit. It is also possible to power it using an external 10-30VDC power supply, as shown below

- After connecting to the power supply, remove the battery tab to enable battery backup power
Logger ကိုပြင်ဆင်ခြင်း။
- Connect the logger to the PC using the USB cable supplied. Download the NXperience software ဒီမှာ or by using the QR code. Then install and start it.

Configuration ကိုဖတ်ပါ
To Start, click “Read Device” to pull in the initial configuration already on the device
အချိန်ဇုန်ဖွဲ့စည်းမှု
Select the correct Time Zone for your location
အာရုံခံစနစ်ဖွဲ့စည်းမှု
Select the correct sensor(s) for each channel. For the E1-21 RTD, use the PT100 sensor type. For the E1-25 thermocouple, use the type T thermocouple type
Configure Logging Interval
Set the log rate to the desired time interval for uploading data. We recommend 15 – 30 minutes as the typical upload interval for most applications.
Ethernet ဖွဲ့စည်းမှု
In most cases, the logger can be set to use DHCP, and it will automatically get an IP address. If this is not the case, see the manual on how to enter the IP address, DNS, and gateway info. When the settings are complete, click the arrow to upload the settings to the logger. After the upload is complete, the logger should start displaying current values within a few minutes.
DIsplay Reference 
Indicates Ethernet is active & connected
Indicates the logger is recording
Indicated that an alarm has been triggered
Indicates which channel is in alarm
ဘက်ထရီအဆင့်ကိုညွှန်ပြသည်
Sign In To Online Account
Sign in to your account at www.monitor.accsense.com using the credentials emailed to you. You can scan the QR code on the next page for the link.
Change Device & Sensor Info
Click on Devices and then click the pencil icon to change the device name and settings.
Add Users & Update Contact Information
Click on Users to switch to the User Configuration page. Click Create User to add a new user. Click the Pencil icon next to an existing user to change their settings.
View Data & Configure Alarms
Click on Sensor Summary to bring up the devices and sensors with the current values and alarm status. Click the graph icon under history to bring up a chart for the sensor. A Red Clock icon under Alarm Status will indicate a sensor currently in alarm state. Click the Pencil icon in the Sensor List to change the sensor name. Click the Clock icon under Alarms to bring up the alarm setting window below
The Alarms window will show the alerts currently set for the sensor. Click the Pencil icon to change the Alert Settings. The first screen is used to set the Alarm Trigger, Trigger Point, and Filter. Click the Continue button to select the alarm recipients and type of notification.
View စာရင်းစစ်မှတ်တမ်း
Click the Audit Log button to view a list of Alarms and Notifications.
နောက်ထပ် အချက်အလက်
8437 Mayfield Rd, Unit 104A
Chesterland, OH
၇၃၆-၇၈၄-၆၀၉၄
www.dataloggerinc.com
အမြဲမေးလေ့ရှိသောမေးခွန်းများ
Q: How do I change the sensor type for a specific channel?
A: In the Sensor Configuration section of the software, select the correct sensor type for each channel.
Q: Can I use a different power supply other than the provided options?
A: Yes, you can use an external 10-30VDC power supply to power the Ethernet Pro.